Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan

Product Details
Customization: Available
Material: Stainless Steel
Usage: Coal Mine
Still deciding? Get samples of US$ 1000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Overseas Services
The supplier provides overseas services and supports countries including Denmark, Colombia, India, Georgia.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (30)
  • Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
  • Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
  • Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
  • Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
  • Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
  • Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Contact Us
Overview

Basic Info.

Model NO.
KCS
Pressure
High Pressure
Certification
CE
Product Number
Kcs-90d
Working Resistance (PA)
1000
Rated Treatment Air Volume (M3/Min)
90
Motor Power
5.5
Respirable Dust Dust Removal Efficiency
≥(90-9
Liquid to Gas Ratio (L/M3)
0.05-0.07
Total Dust Removal Efficiency (%)
≥97%
Air Inlet Outer Diameter φ (mm)
510
Transport Package
Standarad Package
Specification
mm
Trademark
China Coal Group
Origin
China
Production Capacity
100set/Month

Packaging & Delivery

Package Size
30.00cm * 30.00cm * 30.00cm
Package Gross Weight
20.000kg

Product Description

Mining Axial Flow Fan Trial Exhuast Fan Mining Mining Frame Cooling Fan
Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan

Product Description


Introduction Of Mining Axial Flow Fan Trial Exhuast Fan Mining Mining Frame Cooling Fan

1. Main use and scope of application
KCS series mining wet dust removal fan (hereinafter referred to as dust removal fan) has the dual functions of ventilation and dust removal. It is mainly suitable for in-situ purification of dusty air at the dust-producing operation point where coal dust is concentrated, and can partially eliminate toxic and harmful gases. ingredient. Effectively adapt the working environment to industrial hygiene standards. Ensure the health of the miners and the safe production of the mine.
Dust removal fan implementation standards: enterprise standard Q/SDTS001-2007 "KCS series mining wet dust removal fan" and operation standard MT159 "general technical conditions for mining dust collector".zmwm20
2. Structural features
(1) KCS series dust removal fan is mainly composed of four parts: mixing chamber, clean room, fan and dehydration device. The structural parts are welded by steel plates, and the air ducts of each section are connected by flange bolts, and the impeller and the motor are directly connected. The machine is compact, rugged, safe to use and easy to maintain.
(2) The junction box of the motor is located outside the fan casing to facilitate wiring. There are six terminal blocks and one grounding terminal in the junction box. The user selects the wiring method according to the power supply voltage. When the power supply voltage is 380V, the Δ connection method is selected; when the power supply voltage is 660V, the Y connection method is selected. Explosion-proof type with motor: explosion-proof type; explosion-proof mark; ExdI fan is wired according to the factory.
Product Parameters


Parameter Of Mining Axial Flow Fan Trial Exhuast Fan Mining Mining Frame Cooling Fan

Product number Working resistance (Pa) Rated treatment air volume (m3/min)) Motor Power Respirable dust dust removal efficiency (%) Liquid to gas ratio (L/m3) Total dust removal efficiency (%)) Air inlet outer diameter φ (mm)
KCS-90D 1000 90 5.5 ≥(90-98)% 0.05-0.07 ≥97% 510
KCS-120D 1000 120 7.5 ≥(90-98)% 0.03-0.05 ≥97% 510
KCS-145D 1200 145 11 ≥(90-98)% 0.04-0.06 ≥97% 570
KCS-180D 1200 180 15 ≥(90-98)% 0.03-0.09 ≥97% 570
KCS-225D 1200 225 18.5 ≥(90-98)% 0.03-0.04 ≥97% 640
KCS-265D 1200 265 22 ≥(90-98)% 0.03-0.04 ≥97% 640
KCS-320D 1200 320 30 ≥(90-98)% 0.03-0.04 ≥97% 640
KCS-418D 1200 418 37 ≥(90-98)% 0.03-0.04 ≥97% 720
 
Detailed Photos


Photos Of Mining Axial Flow Fan Trial Exhuast Fan Mining Mining Frame Cooling Fan

 
Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
Company Profile

 

Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan
Contact Us

 

Mining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling FanMining Axial Fan Kcs Coal Mine Underground Fan Frequency Conversion Cooling Fan

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now