Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Product Details
Customization: Available
Material: Stainless Steel
Usage: Coal Mine
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Overseas Services
The supplier provides overseas services and supports countries including Denmark, Colombia, India, Georgia.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (30)
  • Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan
  • Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan
  • Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan
  • Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan
  • Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan
  • Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan
Find Similar Products

Basic Info.

Flow Direction
Axial Flow
Pressure
High Pressure
Certification
CE
Fan Model
K40-4-No8#Fan
Machine Number
8
Speed R/Min
1450
Power (Kw)
5.5
Air Volume M3/S
4.4-9.5
Full Pressure PA
108-497
Transport Package
Standarad Package
Specification
mm
Trademark
china coal
Origin
China
Production Capacity
100set/Month

Product Description

Introduction Of Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

K40 Series mine energy-saving fan is specially designed according to the needs of various non-coal mines such as metallurgy, nonferrous metals, gold, chemicals, building materials and nuclear industry. It can be used as the main fan and auxiliary fan, which can be installed on the surface or in the underground. It is suitable for combined operation of multiple fans. It is an ideal machine station fan for all levels of multi-stage multi-stage machine station ventilation system. It is also suitable for ventilation in large workshops, tunnels, civil air defense projects and other occasions.zmwm02
Main features of the fan:
1. The twisted airfoil blade is used, the aerodynamic efficiency is high, and the energy saving effect is extremely remarkable.
2, various performance, complete specifications, can be well matched with a variety of resistance and airflow type ventilation network, can maintain long-term efficient operation.
3. With steady flow ring device, there is no hump in the characteristic curve, no risk of surge, safe and stable operation under any resistance state, and suitable for combined operation of multiple fans.
4. The structure of the motor and the impeller is directly connected, the overall stability is good, the installation is convenient, the maintenance is easy, and the device has low resistance.
5, compact structure, good moisture resistance. The main body of the fan is made of steel plate and section steel. The blade is made of steel plate material. It is hollow, and the blade and the whole machine have high strength. It has strong ability to resist downhole blasting shock wave. It can be installed on the surface and is suitable for installation in underground. It is especially suitable as a multi-stage machine. The station fan of the station ventilation system.
6, can reverse the wind, the wind rate is greater than 60%, no need to build a counter-wind.
7. The blade installation angle is adjustable, and the fan condition can be adjusted at any time according to the changes in mine production.
8. The amount of civil works is small, which can save a lot of investment.
9. The noise is low.

Parameter Of Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Fan model Machine number Speed r/min Power (kW) Air volume m3/s Full pressure Pa
K40-4-NO8#Fan 8 1450 5.5 4.4-9.5 108-497
K40-4-NO9#Fan 9 1450 11 6.2-13.5 136-629
K40-4-NO10#Fan 10 1450 15 8.5-18.6 168-776
K40-4-NO11#Fan 11 1450 30 11.3-24.7 203-9390
K40-4-NO12#Fan 12 1450 37 14.7-32.1 242-1118
K40-4-NO13#Fan 13 1450 55 18.7-40.8 284-1312
K40-4-NO14#Fan 14 1450 90 23.4-50.9 329-1521
K40-4-NO15#Fan 15 1450 110 28.7-62.6 378-1746
K40-6-NO7#Fan 7 980 1.1 2.0-4.3 38-174
K40-6-NO8#Fan 8 980 2.2 3.0-6.4 49-227
K40-6-NO9#Fan 9 980 3 4.2-9.1 62-287
K40-6-NO10#Fan 10 980 5.5 5.8-12.5 77-355
K40-6-NO11#Fan 11 980 7.5 7.7-16.7 93-429
K40-6-NO12#Fan 12 980 15 9.9-21.7 111-510
K40-6-NO13#Fan 13 980 18.5 12.6-27.5 130-599
K40-6-NO14#Fan 14 980 30 15.8-34.4 150-695
K40-6-NO15#Fan 15 980 37 19.4-42.3 173-798
K40-6-NO16#Fan 16 980 55 23.6-51.4 197-908
K40-6-NO17#Fan 17 980 75 28.3-61.6 222-908
K40-6-NO18#Fan 18 980 90 33.6-73.1 249-1149
K40-6-NO19#Fan 19 980 110 39.5-86.0 277-1280
K40-6-NO20#Fan 20 980 160 46.0-100.3 307-1418
K40-6-NO21#Fan 21 980 200 53.3-116.1 339-1563
K40-6-NO22#Fan 22 980 250 61.3-113.4 372-1716
K40-8-NO11#Fan 11 730 4 5.7-12.4 52-238
K40-8-NO12#Fan 12 730 5.5 7.4-16.1 61-283
K40-8-NO13#Fan 13 730 7.5 9.4-20.5 72-332
K40-8-NO14#Fan 14 730 11 11.8-25.6 84-386
K40-8-NO15#Fan 15 730 15 14.5-31.5 96-443
K40-8-NO16#Fan 16 730 22 17.6-38.3 109-504
K40-8-NO17#Fan 17 730 30 21.1-45.9 123-568
K40-8-NO18#Fan 18 730 37 25.0-54.5 138-637
K40-8-NO19#Fan 19 730 55 29.4-64.1 154-710
K40-8-NO20#Fan 20 730 75 34.3-74.7 170-787
K40-8-NO21#Fan 21 730 90 39.7-86.5 188-867
K40-8-NO22#Fan 22 730 110 45.7-99.4 206-952
K40-8-NO23#Fan 23 730 132 52.2-113.6 225-1041
K40-8-NO24#Fan 24 730 160 59.3-129.1 245-1133
K40-8-NO25#Fan 25 730 200 67.0-146 266-1229
K40-8-NO26#Fan 26 730 250 75.4-164.2 288-1330
 

Photos Of Underground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Underground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction FanUnderground Ventilation Tunnel Ventilation Fans Dust Extraction Fan

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Product Groups
More