• Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
  • Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
  • Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
  • Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
  • Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
  • Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans

Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans

Material: Stainless Steel
Usage: Coal Mine
Flow Direction: Axial Flow
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans pictures & photos
Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
US $180-250 / Piece
Min. Order: 10 Pieces
Diamond Member Since 2012

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
FD Series
Pressure
High Pressure
Certification
CE
Num
№4.0
Rotating Speed(R/Min)
2900
Air Volume(M3/Min)
136~89
Full Pressure(PA)
256~2050
Motor Model
Y90L-2
Pressure (PA)
256~2050
Matching Power(Kw)
2*2.2
Transport Package
Standarad Package
Specification
mm
Trademark
china coal
Origin
China
Production Capacity
100set/Month

Product Description

Introduction of FD Series Axial Flow Mining Fan Underground Mining Ventilation Fans 

The FD series mine counter-rotating axial flow partial ventilator is mainly used for non-coal mines, which can be used for medium and long-distance ventilation of mine mining face. It is a new generation of energy-saving ventilators with a wide range of application.zmwm02
1. FD series mine axial flow fan has the characteristics of reasonable structure, complete specifications, high efficiency, obvious energy saving effect, low noise and long air supply distance. If the length of the roadway is less than 2000m, the air can be blown normally without moving the ventilator, which reduces the labor intensity of the workers and saves ventilation time. It is an ideal equipment for local ventilation in non-coal mines.

2. The FD series mine counter-rotating axial flow local ventilator consists of two working hosts, and the two-stage impeller rotates in opposite directions. That is, the first-stage impeller rotates clockwise, the second-stage impeller rotates counterclockwise, and the number of the two-stage blades is prime. The air is extracted by the primary impeller and sent out after being pressurized by the secondary impeller. In addition to increasing the airflow energy, the second-stage impeller also has the function of the static guide vane in the common axial flow fan. It can smooth the airflow impact while increasing the airflow energy and reduce the wake vortex. , reducing noise.

3. The FD series mine rotary axial flow local ventilator adopts an outsourced double-type muffler, which has ultra-low noise characteristics and has a significant effect on changing the noise environment of the downhole restraint space.

4. The main body of FD series mine rotary axial flow fan adopts steel plate welding structure. The inside of the blade and the casing are treated with anti-corrosion and moisture proof, so that the fan can run for a long time in humid environment, effectively solving other conditions caused by the fan. Corrosion problem.

5, FD series mining rotary axial flow local fan supporting motor is Y series three-phase asynchronous motor, voltage class is 380V. The ventilator can be set up without stopping the oil and discharge device to ensure that the fan is injected and drained during operation, ensuring long-term reliable and safe operation of the motor in harsh environments.
6. The gas temperature of the FD series mining rotary axial flow local ventilator is -20 °C ~ +40 °C, the relative humidity is not more than 95% (at 25 °C), and the altitude should not exceed 1000m. The dust contained in the medium conveyed by the ventilator shall not exceed 200mg/m3. The ventilator mainly transports air and non-corrosive non-self-igniting medium without viscous substances, and the dust content should not exceed 200mg/m3.

Parameter of FD Series Axial Flow Mining Fan Underground Mining Ventilation Fans 

 
Num Rotating speed(r/min) Air volume(m3/min) Full pressure(Pa) Motor model Matching power(kW)
№4.0 2900 136~89 256~2050 Y90L-2 2×2.2
150~100 325~2500 Y100L-2 2×3
165~109 375~3040 Y112M-2 2×4
№5.0 2900 217~145 275~2060 Y112M-2 2×4
240~161 325~2540 Y132S1-2 2×5.5
266~178 400~3155 Y132S2-2 2×7.5
№5.6 2900 286~188 275~2850 Y132S2-2 2×7.5
324~215 375~3690 Y160M1-2 2×11
358~238 440~4560 Y160M2-2 2×15
№6.3 2900 410~237 400~4775 Y160M2-2 2×15
442~256 460~5475 Y160L-2 2×18.5
468~274 525~6125 Y180M-2 2×22
518~318 640~7310 Y200L1-2 2×30
№7.1 2900 608~352 523~6228 Y200L1-2 2×30
652~377 602~7163 Y200L2-2 2×37
696~402 686~8161 Y225M-2 2×45
№8.0 2900 817~473 605~7200 Y225M-2 2×45
874~506 692~8230 Y250M-2 2×55
970~560 850~9950 Y280S-2 2×75
№9.0 1450 831~480 394~4710 Y200-4 2×30
890~520 450~5120 Y225S-4 2×37
950~550 520~6170 Y225M-4 2×45
№10.0 1450 1171~677 514~6131 Y250M-4 2×55
1300~750 630~7540 Y280S-4 2×75
1380~800 710~8520 Y280M-4 2×90
№11.2 1450 1650~950 650~7690 Y280M-4 2×90
1770~1020 750~8790 Y315S-4 2×110
1880~1090 850~9930 Y315M-4 2×132

Photos of FD Series Axial Flow Mining Fan Underground Mining Ventilation Fans 

Fd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation FansFd Series Axial Flow Mining Fan Underground Mining Ventilation Fans

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans pictures & photos
Fd Series Axial Flow Mining Fan Underground Mining Ventilation Fans
US $180-250 / Piece
Min. Order: 10 Pieces
Diamond Member Since 2012

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
100000000 RMB
Plant Area
501~1000 square meters