Trial Exhuast Fan Mining Mining Axial Flow Fan Mining Frame Cooling Fan
Product Description
Introduction Of Trial Exhuast Fan Mining Mining Axial Flow Fan Mining Frame Cooling Fan
1. Main use and scope of application
KCS series mining wet dust removal fan (hereinafter referred to as dust removal fan) has the dual functions of ventilation and dust removal. It is mainly suitable for in-situ purification of dusty air at the dust-producing operation point where coal dust is concentrated, and can partially eliminate toxic and harmful gases. ingredient. Effectively adapt the working environment to industrial hygiene standards. Ensure the health of the miners and the safe production of the mine.
Dust removal fan implementation standards: enterprise standard Q/SDTS001-2007 "KCS series mining wet dust removal fan" and operation standard MT159 "general technical conditions for mining dust collector".zmwm20
2. Structural features
(1) KCS series dust removal fan is mainly composed of four parts: mixing chamber, clean room, fan and dehydration device. The structural parts are welded by steel plates, and the air ducts of each section are connected by flange bolts, and the impeller and the motor are directly connected. The machine is compact, rugged, safe to use and easy to maintain.
(2) The junction box of the motor is located outside the fan casing to facilitate wiring. There are six terminal blocks and one grounding terminal in the junction box. The user selects the wiring method according to the power supply voltage. When the power supply voltage is 380V, the Δ connection method is selected; when the power supply voltage is 660V, the Y connection method is selected. Explosion-proof type with motor: explosion-proof type; explosion-proof mark; ExdI fan is wired according to the factory.
Product Parameters
Parameter Of Trial Exhuast Fan Mining Mining Axial Flow Fan Mining Frame Cooling Fan
Product number |
Working resistance (Pa) |
Rated treatment air volume (m3/min)) |
Motor Power |
Respirable dust dust removal efficiency (%) |
Liquid to gas ratio (L/m3) |
Total dust removal efficiency (%)) |
Air inlet outer diameter φ (mm) |
KCS-90D |
1000 |
90 |
5.5 |
≥(90-98)% |
0.05-0.07 |
≥97% |
510 |
KCS-120D |
1000 |
120 |
7.5 |
≥(90-98)% |
0.03-0.05 |
≥97% |
510 |
KCS-145D |
1200 |
145 |
11 |
≥(90-98)% |
0.04-0.06 |
≥97% |
570 |
KCS-180D |
1200 |
180 |
15 |
≥(90-98)% |
0.03-0.09 |
≥97% |
570 |
KCS-225D |
1200 |
225 |
18.5 |
≥(90-98)% |
0.03-0.04 |
≥97% |
640 |
KCS-265D |
1200 |
265 |
22 |
≥(90-98)% |
0.03-0.04 |
≥97% |
640 |
KCS-320D |
1200 |
320 |
30 |
≥(90-98)% |
0.03-0.04 |
≥97% |
640 |
KCS-418D |
1200 |
418 |
37 |
≥(90-98)% |
0.03-0.04 |
≥97% |
720 |
Detailed Photos
Photos Of Trial Exhuast Fan Mining Mining Axial Flow Fan Mining Frame Cooling Fan
Company Profile