Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser

Product Details
Customization: Available
After-sales Service: Online Video Services
Warranty: 1
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Overseas Services
The supplier provides overseas services and supports countries including Denmark, Colombia, India, Georgia.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
CCC
to see all verified strength labels (30)
  • Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser
  • Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser
  • Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser
  • Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser
  • Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser
  • Vehicle Gas Emission Analyser Automotive Exhaust Gas Analyser
Find Similar Products

Basic Info.

Model NO.
SV-5Q
Customized
Non-Customized
Portable
Portable
Certification
CE, RoHS, TUV, BV
Gas
CO2
Type
Electrochemical Gas Analyzer
Brand
China Coal
Preheating Time
10min
Weight
10kg
Barometric Pressure
70.0~106kpa
Power Supply
AC220V 50Hz
Warm up Time
10minutes
Rotate Speed
0~10000rpm
Oil Temperature
0-120degree Centigrade
Volume
460 * 315 * 225mm
Transport Package
as Required
Trademark
chinacoal
Origin
Shandong, China
HS Code
8501109901
Production Capacity
50, 000 PCS/Year.

Product Description

Automobile Exhaust Gas Analyzer Introduction

 

 

 

1)SV-5Q automobile exhaust gas analyzer(hereinafter referred to as the analyzer) may, in accordance with NDIR (Non-Dispersive Infra-Red) method, via micro-computer analysis, directly measure the thickness of HC, CO and CO 2 in the exhaust gas of vehicles and inspect the density of NO and O2 via Electrochemical sensor so as to calculate excess air coefficient λ.zmwm07

 

2)It is composed of complete imported machinery cores, boasts the advantages of accuracy measurement, high endurance and speed. As an Intelligent Equipment, it is equipped with Microprocessor, LCD and Chinese language interface. Besides, it also has optional equipments such as Induction Tachometer, temperature sensor, inner Micro Printer for customers to purchase.

The newly-added Storage function can detect Engine's speed and Lubricant's Temperature while measuring tail gas, then store and print the results.

 

3)Besides detecting functions, its computer programs on detection under Two-speed Idle, written by us according to (limits and measurement methods for exhaust pollutants from vehicles equipped ignition engine under two-speed idle conditions and simple driving mode conditions), can control the process of detection automatically, so it's convenient to use.

 

4)The analyzer has small size, light weight, storage of 500 groups' data of exhaust gas measurements. Particularly it is suitable for checking along the road. It's utilized for auto-manufacturing factories, vehicle inspection stations and garages.
 

Automobile Exhaust Gas Analyzer Parameter

 

 

 

 

exhaust gas analyzer

 

measuring range

CO:0~10.0 10-2(%) CO2:0~20.0 10-2(%) HC:0~10000 10-6(ppm) O2:0~25.0 10-2(%) NO:0~5000 10-6(ppm)

Choose: oil temperature:18ºC~150ºC speed:100~20000rpm

Repeatability error

≤±2%

Zero drift

CO:±0.06 10-2(%)/4h CO2:±0.5 10-2(%)/4h HC:±30 10-6(ppm)/4h

O2:±0.1 10-2(%)/4h NO:±25 10-6(ppm)/4h

Distance drift

No more than the permissible error value(4 hours)

 

Indication error

CO:±5%(absolute error,±0.06 10-2 )

CO2:±5%(absolute error,±0.5 10-2)

HC:±5%(absolute error,±12 10-6   )±5%(absolute error,4001~10000ppm)

O2:±5%(absolute error,±0.1 10-2)    NO:±4%(absolute error,±25 10-6)

 

environment condition

oil temperature:±2ºC(relative error) speed:±1.0%(relative error) temperature:0ºC~40ºC humidity:≤80% atmospheric pressure:60~105KPa

Power Supply:AC 220V±10%;50Hz±1Hz

Preheating time

10min

Weight

10Kg

Volume

460 * 315 * 225mm

 

Sampling method

tail gas : Direct sampling,Sampling tube length 5m,Sampling probe length 900mm;

oil temperature:The temperature measuring head is inserted into the bore of

the engine oil gauge,insert lengthsame with length,block the plug by rubber,in case of oil spray,conductor length:5m;

speed:Put the speed clamp on tachometer on a high tension cord of a gasoline

 Automobile Exhaust Gas Analyzer Photos

Vehicle Gas Emission Analyser Automotive Exhaust Gas AnalyserVehicle Gas Emission Analyser Automotive Exhaust Gas AnalyserVehicle Gas Emission Analyser Automotive Exhaust Gas AnalyserVehicle Gas Emission Analyser Automotive Exhaust Gas AnalyserVehicle Gas Emission Analyser Automotive Exhaust Gas AnalyserVehicle Gas Emission Analyser Automotive Exhaust Gas Analyser

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
People who viewed this also viewed